Redesigned Structure of the Differential Pressure Valve
In the original design, the differential pressure valve had different surface areas on either side. When the system generated hydraulic pressure, the pressure in the left and right chambers was equal. However, because the piston area in the right chamber was larger than that in the left chamber, the piston moved to the left once the hydraulic pressure reached approximately 1 MPa, causing the alarm to remain continuously active, even after pressure was relieved. This design was flawed and did not function as a differential pressure alarm.
Our company implemented a structural redesign: we introduced a floating sleeve. With the floating sleeve in place, the piston always remains in a central position, and the alarm remains in an off state, preventing false alarms. Only when there is a leak in one of the chambers, causing a pressure difference of 0.8-1.2 MPa between the two chambers, will the piston move towards the chamber with the lower pressure, triggering the alarm and achieving the differential pressure alarm function.